Clinical application of 3D printing combined with ECMO in the treatment of severe aortic stenosis with low ejection fraction by TAVR
Author:
Affiliation:

Department of Cardiovascular Surgery, Xijing Hospital, Air Force Medical University, Xi’an, Shaanxi 710032, China)

Clc Number:

R5;R6

  • Article
  • | |
  • Metrics
  • |
  • Reference [19]
  • | | | |
  • Comments
    Abstract:

    Aim To investigate the feasibility and effectiveness of 3D printing and extracorporeal membrane oxygenation assistant in transcatheter aortic valve replacement (TAVR) of severe aortic stenosis patients. Methods From November 2018 to May 9,0 patients with severe aortic stenosis underwent transcatheter aortic valve replacement assisted by ECMO in Xijing Hospital of Air Force Military Medical University. The preoperative left ventricular ejection fraction (LVEF) was (30.3%±10.5%). The preoperative cardiac function grade of all patients was Ⅳ grade(NYHA). Before operation, CT data of all patients were collected and reconstructed. Their cardiovascular models were made by using 3D printing technology. All preoperative evaluation, operation scheme determination and preoperative conversation were done with 3D printing models. Results All the 10 patients received TAVR successfully. The hemodynamic indexes were stable in the perioperative period. The operation time was (192.5±30.3) min, and the DSA irradiation time was (40.5±3.2) min. The ECMO assistant time was (60.5±23.9) min. The echocardiography showed the heart function was improved. The LVEF was (48.5%±4.3%). Conclusion It is very difficult for patients with very high-risk aortic stenosis to be treated with TAVR. 3D printing technology can provide doctors and nurses an intuitive model, assist doctors-patient communication and preoperative evaluation. ECMO can ensure the perioperative hemodynamic stability of patients and provide effective cardiopulmonary function support, thus to improve the success rate of TAVR.

    Reference
    [1] Gaede L, Kim W, Liebetrau C, et al.Pacemaker implantation after TAVI:predictors of AV block persistence.Clin Res Cardiol, 8,7(1):60-69.
    [2] Falk V, Baumgartner H, Bax JJ, et al.2017 ESC/EACTS guidelines for the management of valvular heart disease.Eur J Cardiothorac, 7,2(4):616-664.
    [3] Nishimura RA, Otto CM, Bonow RO, et al.2017 AHA/ACC focused update of the 2014 AHA/ACC guideline for the management of patients with valvular heart disease:a report of the American College of Cardiology/American Heart Association task force on clinical practice guidelines.Circulation, 7,5(25):e1159-e1195.
    [4] Uehara K, Minakata K, Saito N, et al.Use of extracorporeal membrane oxygenation in complicated transcatheter aortic valve replacement.Gen Thorac Cardiovas, 7,5(6):329-336.
    [5] Chiu P, Fearon WF, Raleigh LA, et al.Salvage extracorporeal membrane oxygenation prior to “bridge” transcatheter aortic valve replacement.J Card Surg, 6,1(6):403-405.
    [6] Dolmatova E, Moazzami K, Cocke TP, et al.Extracorporeal membrane oxygenation in transcatheter aortic valve replacement.Asian Cardiovasc Thorac Ann, 7,5(1):31-34.
    [7] Trenkwalder T, Pellegrini C, Holzamer A, et al.Emergency extracorporeal membrane oxygenation in transcatheter aortic valve implantation:a two-center experience of incidence, outcome and temporal trends from 2010 to 2015.Catheter Cardiovasc Interv, 8,2(1):149-156.
    [8] Singh V, Damluji AA, Mendirichaga R, et al.Elective or emergency use of mechanical circulatory support devices during transcatheter aortic valve replacement.J Interv Cardiol, 6,9(5):513-522.
    [9] Kuhn E, Madershahian N, Rudolph T, et al.Catheter insertion via extracorporeal membrane oxygenation cannula during transcatheter aortic valve implantation.Thorac Cardiovasc Surg Res, 6,5(01):41-43.
    [10] Wang L, Huang L, Li X, et al.Three-dimensional printing PEEK implant:a novel choice for the reconstruction of chest wall defect.Ann Thorac Surg, 9,7(3):921-928.
    [11] Zhou X, Vannan MA, Qian Z.3D printing for transcatheter aortic valve replacement:integrating anatomy and physiology to plan, predict and optimize procedural outcomes.Int J Cardiol, 8,8:334-335.
    [12] Ripley B, Kelil T, Cheezum MK, et al.3D printing based on cardiac CT assists anatomic visualization prior to transcatheter aortic valve replacement.J Cardiovasc Comput Tomogr, 6,0(1):28-36.
    [13] Foley TA, El Sabbagh A, Anavekar NS, et al.3D-printing:applications in cardiovascular imaging.Curr Radiol Rep, 7,5(9):1-13.
    [14] 李兰兰, 王建浩, 逯登辉, 等.3D打印技术辅助经皮介入治疗主动脉瓣狭窄20例临床治疗分析.中华胸心血管外科杂志, 2019(9):561-563.
    [15] 丁鹏, 刘洋, 徐臣年, 等.3D打印技术结合经心尖导管主动脉瓣植入15例.中国体外循环杂志, 9,7(5):261-264.
    [16] 金屏, 刘洋, 唐嘉佑, 等.经皮球囊扩张式覆膜支架置入治疗先天性主动脉缩窄的临床疗效分析.中国体外循环杂志, 8,6(6):366-368.
    [17] Fan Y, Yang F, Cheung GS, et al.Device sizing guided by echocardiography-based three-dimensional printing is associated with superior outcome after percutaneous left atrial appendage occlusion.J Am Soc Echocardiogr, 9,2(6):708-719.
    [18] Blanke P, Naoum C, Webb J, et al.Multimodality imaging in the context of transcatheter mitral valve replacement:establishing consensus among modalities and disciplines.JACC Cardiovasc Imaging, 5,8(10):1191-1208.
    [19] Wunderlich NC, Beigel R, Ho SY, et al.Imaging for mitral interventions:methods and efficacy.JACC:Cardiovasc Imaging, 8,1(6):872-901.
    Related
    Cited by
    Comments
    Comments
    分享到微博
    Submit
Get Citation

JIN Ping, LIU Yang, GUO Hong, YANG Jingjuan, NING Lijuan, ZHANG Yan, JIN Yan, YANG Jian. Clinical application of 3D printing combined with ECMO in the treatment of severe aortic stenosis with low ejection fraction by TAVR[J]. Editorial Office of Chinese Journal of Arteriosclerosis,2020,28(10):841-846.

Copy
Share
Article Metrics
  • Abstract:1013
  • PDF: 736
  • HTML: 0
  • Cited by: 0
History
  • Received:April 10,2020
  • Revised:September 05,2020
  • Online: October 20,2020
Article QR Code